SYS-220BT-HNC9R
Print
Intergrated Board
Key Features
- Key Applications
- Mission Critical HPC
- Virtualized Big Data Analytics
- High-Density Storage RAID Array
Key Features
Four hot-pluggable systems (nodes) in a 2U form factor. Each node supports the following:
1. Socket P+ (LGA 4189) support 3rd Gen Intel® Xeon® Scalable processors
- 2. Intel® C621A
- 3. 20 DIMM Slots (16 DIMM Slots + 4 Intel® Optane™ Persistent Memory Slots)
- 4. 1 PCI-E 4.0 x16 (LP) slot;
Tool-less support
Internal PCI-E 3.0 x8 for 2 M.2 NVMe/SATA support onboard
Optional NVMe Boot Controller via AOC-SMG3-2M2-B
- 5. Network connectivity via AIOM (OCP 3.0 compliant)
- 6. 6 Hot-swap 2.5" drive bays; 6 PCI-E 4.0 NVMe/SAS/SATA 2.5" drives
- 7. 4 cooling fans per 2U enclosure, 16.5K RPM; Shared Cooling Design
Liquid Cooling Support
- 8. 2600W Redundant Power Supplies Titanium Level (96%+); Shared Power Design
- 9. Built-in SAS3 Support via Broadcom SAS3908
Specifications
|
|
Parts List
![]() |
|||
Parts List - (Items Included) | |||
![]() |
|||
![]() |
Part Number![]() |
Qty![]() |
Description![]() |
Motherboard / Chassis |
MBD-X12DPT-B6 CSE-217BQ-000NP |
4 1 |
Super X12DPT-B6 Motherboard 2U Chassis |
Add-on Card / Module | AOC-S3908L-H8IR-16DD-P | 4 | 8 int 12Gb/s ports, x8 Gen4, ROC - LP, 16 HDD w/ exp,RoHS |
Add-on Card / Module | AOC-SMG3-2H8M2-BW-P | 4 | 2x Hybrid M.2 riser carrier card for X12 BigTwin,RoHS |
Backplane | BPN-NVME4-217BHQ-S6 | 1 | 2U 24-Slot 4-Node BigTwin Backplane Supports up to 6xNVMe4/SAS4/SATA3 per Node |
Cable 1 | CBL-PWCD-0376-IS | 2 | PWCD,US,IEC60320 C19 TO C20,940mm (3ft),14AWG,15A,250V,Black |
Cable 2 | CBL-SAST-1234F-100 | 4 | Slimline x8 (STR) to Slimline x8(STR),FFC,FOLD,33.5CM,10 |
Drive Tray(s) | MCP-220-00144-0B-BULK | 24 | Black Gen3 hot-swap 2.5 inch HDD tray with lock, orange tab |
Air Shroud | MCP-310-21730-0B | 4 | BigTwin 2U4N plastic air shroud for X12DPT-B |
Riser Card | RSC-PR-6-X2 | 4 | 1U RHS TwinPro Riser card with one PCI-E 4.0 x16 slot,HF,RoH |
Heatsink / Retention | SNK-P0077PW | 4 | 1U Passive CPU HS 92mm Width for X12 Whitley Platform |
Heatsink / Retention | SNK-P0077VM | 4 | X12 ICX/CPX CPU Heatsink (78x113x25.5mm), VC Base w/ Channel |
*Power Supply | PWS-2K60A-1R | 2 | 1U 2600W Redundant Titanium PWS, 45(W) X 40(H) X 480(L) |
*Power Distributor | PDB-PT217-BGTWN | 1 | 2U Big Twin Power Distributor Board Support Redundant 2KW |
*FAN 1 | FAN-0183L4 | 4 | 80x80x38 mm, 16.5K RPM, Non-hot-swappable Middle Cooling Fan for X11 Twin Pro, X10 and X11 Big Twin Series Servers |
*Rail Set | MCP-290-00172-0N | 1 | 2U non-tip rail set, quick release, default for 2,3U 17.6";W |
*Fan Holder | MCP-320-21702-0N | 2 | Bigtwin fan holder (with 4.1mm rubber feet)(hold 2 80x38 fans) |
![]()
|
![]() |
|||
Optional Parts List | |||
![]() |
|||
Part Number | Qty | Description | |
CacheVault for RAID Controller | BTR-CVPM05 | - | Broadcom CacheVault |
BKT-BBU-BRACKET-05 | - | Mounting Bracket | |
HDD Dummy Tray | MCP-220-00185-0N | 4 | 2.5" HDD tray dummy cover for 2 slot |
M.2 NVMe RAID Controller | AOC-SMG3-2M2-B-P | - | 2x M.2 NVMe RAID Controller Card |
SPI Capable TPM 1.2 | AOM-TPM-9671H-S | - | SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor |
SPI Capable TPM 2.0 | AOM-TPM-9670H-S | - | SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor |
SPI Capable TPM 2.0 with FIPS 140-2 | AOM-TPM-9670H-FIPS | - | SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor, Supporting FIPS 140-2 |
SuperCloud Composer License | SFT-SDDC-SINGLE | - | SDDC Monitor License - Single License per Monitored host |
System Management Suite | SFT-DCMS-Single | - | Supermicro System Management Software Suite node |
VROC Intel SSD Only | AOC-VROCINTMOD | - | Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only) |
VROC Premium | AOC-VROCPREMOD | - | Intel VROC Premium, RAID 0, 1, 5, 10 |
VROC Standard | AOC-VROCSTNMOD | - | Intel VROC Standard, RAID 0, 1, 10 |