SSG-2029P-E1CR24H
PrintIntergrated Board
Key Features
- - Corporate Database
- Database Processing & Storage
- Enterprise Server
- HPC, Data Center
- iSCSI SAN
- 1. Dual Socket P (LGA 3647) support 2nd Gen Intel® Xeon® Scalable processors (Cascade Lake/Skylake)‡
- 2. 16 DIMMs; up to 4TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM,
Supports Intel® Optane™ DCPMM††
- 3. 3 PCI-E 3.0 x16, 4 PCI-E 3.0 x8 (slot 2 & 3 occupied by controller and JBOD expansion port)
- 4. 24 Hot-swap 2.5" SAS3/SATA3 drive bays including 4 optional NVMe drives;
2 Hot-swap 2.5" SATA3 drive bays (rear),
2x M.2 NVMe. Expander based backplane.
- 5. Broadcom 3108 SAS3 AOC
- 6. 2x 10GBase-T LAN ports with Intel X722 + PHY Intel X557
- 7. Server remote management: IPMI 2.0 / KVM over LAN / Media over LAN
- 8. 3 Hot-swap 8cm redundant PWM fans
- 9. 1200W Redundant Power Supplies Titanium Level (96%)
Specifications
|
|
Parts List
Parts List - (Items Included) | |||
|
Part Number |
Qty |
Description |
Motherboard / Chassis | MBD-X11DPH-T CSE-216BE1C4-R1K23LPB |
1 1 |
Super X11DPH-T Motherboard 2U Chassis |
Add-on Card / Module | AOC-S3108L-H8IR | 1 | LSI 3108 based SAS3 RAID, 12Gb, 8 internal ports, 240HDD - RAID 0,1,10,5,6,50,60, Gen3 x8 Standard Low Profile |
Add-on Card / Module | AOM-SAS3-8I8E-LP | 1 | 8-port Mini SAS HD Int-to-Ext cable adapter w/ LP bracket,HF,RoHS/REACH |
Backplane | BPN-SAS3-216EL1-N4 | 1 | 24-port 2U SAS3 12Gbps single-expander backplane, support up to 20x 2.5-inch SAS3/SATA3 HDD/SSD and 4x NVMe/SAS3/SATA3 storage devices |
Cable 1 | CBL-0099 | 1 | Power extension cable; one HDD to two HDD and two FDD. 35/25/12cm. 22AWG |
Cable 2 | CBL-SAST-0532 | 4 | MINI SAS HD,12G,INT,50CM,30AWG |
Parts | MCP-220-82616-0N | 1 | 12G 2.5x2 Drive Kit w/ Status LED(216B/826B/417B/846X/847B) |
Parts | MCP-260-00042-0N | 1 | STD I/O shield for X9 socket R server MB with Gasket. |
Heatsink / Retention | SNK-P0068PS | 1 | 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism |
Heatsink / Retention | SNK-P0068PSC | 1 | 2U Passive CPU Heat Sink with a Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism |
Power Supply | PWS-1K23A-1R | 2 | AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 360x76x40 mm,HF,RoHS/REACH |
FAN 1 | FAN-0158L4 | 3 | 80x80x38 mm, 10.5K RPM, Optional Middle Cooling Fan for X10 2U Ultra and HFT Series Servers,RoHS/REACH |
Drive Tray(s) | MCP-220-00047-0B | 24 | Black 3rd Gen hot-swap 2.5" HDD tray |
Optional Parts List | |||
Part Number | Qty | Description | |
4 NVMe Drives Support | AOC-SLG3-2E4R CBL-CDAT-0674 CBL-SAST-0590 MCP-220-00121-0B |
2 2 4 4 |
Dual-Port PCIe Gen-3 NVMe Internal Host Bus Adapter 4 Pin to 4 Pin I2C Cable, 30cm, 26AWG, 4 Wires, Pinout 1-1 MINI SAS HD,INT,PCIe NVMe SSD, 70CM,30AWG Black gen-3 2.5 NVMe drive tray |
3108 Cache Protection | BTR-TFM8G-LSICVM02 BKT-BBU-BRACKET-05 |
1 1 |
SuperCap Module Mounting PCIe Card |
Cable | CBL-0099 | 1 | HDD Y-Split Cable |
Global Services & Support | OS4HR3/2/1 OSNBD3/2/1 |
- - |
3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service |
Software | SFT-OOB-LIC | 1 | OOB Management Package (per node license) |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |