SSG-6049SP-DE1CR60
PrintKey Features
- - Big Data & Analytics, Data Lake
- HPC and AI/ML Workloads
- Telco & Cloud Service Providers
- Financial Services & Healthcare Image Archives
- Content Repositories
- Government Data Protection
- 1. Dual Node Twin Architecture, 2x compute Each node controls 30 drives
- 2. Dual Socket P (LGA 3647) support 2nd Gen Intel® Xeon® Scalable processors (Cascade Lake/Skylake)‡
- 3. 16 DIMMs; up to 4TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM,
Supports Intel® Optane™ DCPMM††
- 4. 2 PCI-E 3.0 x16 (HHHL), 1 PCI-E 3.0 x8 (HHHL)
- 5. 60x 3.5"/2.5" Hot-swap SAS3/SATA3 drives, 2x Fixed slim SATA SSD, 2x NVMe M.2 (form factor: 22110)
- 6. Dual Broadcom 3616 controllers (IT Mode) or Broadcom 3916 (H/W RAID)
- 7. Server remote management: IPMI 2.0 / KVM over LAN / Media over LAN
- 8. 6x 8cm hot-swap counter-rotate redundant PWM cooling fans
- 9. 2600W Redundant Power Supplies Titanium Level (96%)
Specifications
|
Parts List
Parts List - (Items Included) | |||
|
Part Number |
Qty |
Description |
Motherboard / Chassis | MBD-X11DSC CSE-947STS-R2K63P |
1 1 |
Super X11DSC Motherboard SC947S 60-Bay top load chassis w/ 2600W titanium PWS, w/o BPN |
Backplane | BPN-ADP-30SAS3-1 | 2 | Adapter board between Expander and HDD BPN for CSE-947H,RoHS |
Backplane | BPN-SAS3-947EB | 4 | HDD Backplane (15-slot) for CSE-947H 60/90-bay top load chassis/server.,RoHS |
Backplane | BPN-SAS3-947EL | 2 | SAS3 expander module for top-load 60/90-bay single/twin/SBB CSE-947 project,RoHS |
Backplane | BPN-SAS3-947SB | 1 | Midplane for topload CSE-947 60/90-bay SBB/Twin/single-node system,RoHS |
Drive Tray(s) | MCP-220-94601-0N | 60 | SC946ED 3.5" / 2.5" tool-less HDD tray |
Cable 1 | CBL-0066 | 2 | 39" 9 PIN COM PORT EXTENSION CABLE |
Cable 2 | CBL-0082 | 2 | Y SPLIT SATA POWER ADAPTER 6" |
Cable 3 | CBL-0473L | 4 | 21CM 30AWG SATA CBL, S-S |
Cable 4 | CBL-OTHR-1062-25 | 2 | [NR] CBL,VGA,DP15/F, to 2X7F/P2.0,25CM,RoHS |
Cable 5 | CBL-OTHR-1103 | 1 | [NR] 60-twin,SlimlineULP x12 to SlimlineLP x8,FFC,100 OHM to 2x8,PH3.0,M, to 2x8,PH3.0,F,6A/pin,18AWG |
Cable 6 | CBL-PWEX-1100-25 | 2 | [NR] MicroFit 2x2F/PH3.0 to 1x4F/PH5.08,25cm,16AWG |
Power Supply | PWS-2K63A-1R | 2 | 2600W Redundant Titanium Power Supply W/PMbus 73.5x40x265mm,RoHS/REACH |
Heatsink / Retention | SNK-P0068PS | 4 | 2U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism |
Notes:
|
Optional Parts List | |||
Part Number | Qty | Description | |
Global Services & Support | OS4HR3/2/1 OSNBD3/2/1 |
- - |
3/2/1-year onsite 24x7x4 service 3/2/1-year onsite NBD service |
Software | SFT-OOB-LIC | 1 | OOB Management Package (per node license) |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
SAS Controllers (choose one of the following) | |||
Part Number | Qty | Description | |
Add-on Module 3616 (IT mode) | AOM-S3616-S-O | 2 | Storage 3616 controller for serviceable 60/90 bay systems. This has two 3616 controller chips, PCI switch, two M.2 connectors, RoHS |
Add-on Card 3916 (HW RAID) (occupies one PCI-E x8 slot) | AOC-S3916L-H16IR-P CBL-SAST-1243-100 |
2 4 |
AOC with SAS3916 controller (U3) and 240PD RAID Key(U39) Slimline x8 (STR) to Slimline x8 (STR), 41.5CM, 100 OHM |
Add-on Card 3916 with Cache Protection (HW RAID) (occupies one PCI-E x8 slot) | AOC-S3916L-H16IR-P CBL-SAST-1243-100 BTR-CVPM05 |
2 4 2 |
AOC with SAS3916 controller (U3) and 240PD RAID Key(U39) Slimline x8 (STR) to Slimline x8 (STR), 41.5CM, 100 OHM Broadcom 05-50039-00 CacheVault w/ 24" Remote Extender |