슈퍼솔루션

슈퍼마이크로 슈퍼마이크로는 기업 컴퓨팅, 스토리지, 네트워킹 솔루션 및 그린 컴퓨팅 기술 분야의 글로벌 리더입니다.

    SYS-221HE-FTNR

    Print

    Key Features

    • 1. Dual Socket E (LGA-4677) 5th/4th Gen Intel® Xeon® Scalable processors
    • 2. 32 DIMM slots supporting up to 8TB of memory; RDIMMs up to DDR5-5600
    • 3. Configurable PCIe slot options up to 8 PCIe 5.0 x8 (6 FHFL+ 2 FHHL) or 4 PCIe 5.0 x16 (3 FHFL + 1 FHHL)
    • 4. Flexible networking options with 2 AIOM networking slots (OCP NIC 3.0 compatible)
    • 5. Up to 6x 2.5" hot-swap drive bays with options to support NVMe/SATA drives
    • 6. 6 heavy duty hot-swap fans with optimal fan speed control
    • 7. Redundant 2000W Titanium level AC power supplies
    Specifications
    Product SKUs
    SuperServer SYS-221HE-FTNR (Silver)
    Motherboard
    Super X13DEM
    Processor
    CPU
    Core Count
    • Up to 60C/120T; Up to 112.5MB Cache per CPU
    Note
    • Supports up to 350W TDP CPUs (Air Cooled)
    GPU
    Max GPU Count
    • Up to 3 double-width or 3 single-width GPU(s)
    Supported GPU
    • Intel PCIe: Intel Data Center GPU Flex 170
    • NVIDIA PCIe: H100,L40,L40S,A40,A10,A2
    • View GPU Options
    CPU-GPU Interconnect
    • PCIe 5.0 x16 CPU-to-GPU Interconnect
    GPU-GPU Interconnect
    • PCIe
    System Memory
    Memory
    • Slot Count: 32 DIMM slots/16 Channels
    • Max Memory (2DPC): Up to 8TB 5600MT/s ECC DDR5 RDIMM
    • View Memory Options
    Memory Voltage
    • 1.1 V
    On-Board Devices
    SATA
    • SATA3 (6Gbps); RAID 0/1/5/10 support
    NVMe
    • NVMe; RAID 0/1/5/10 support (Intel® VROC RAID Key required)
    • View NVMe Options
    Chipset
    • Intel® C741
    Network Connectivity
    • 2x 25GbE SFP28 with Broadcom® BCM57414 (optional)
    • 2x 100GbE QSFP28 with Broadcom® BCM57508 (optional)
    • 2x 100GbE QSFP28 with Intel® E810-CAM2 (optional)
    • 2x 100GbE QSFP28 or 4x 10GbE SFP+ with Intel® X710-BM2 (optional)
    • 2x 200GbE QSFP56 with Mellanox® CX-6 VPI (optional)
    • 2x 100GbE QSFP56 with Mellanox® CX-6 DX (optional)
    • 2x 1GbE BaseT with Intel® I350-AM2 (optional)
    • 4x 10GbE RJ45/SFP+ with Intel® X710-TM4 (optional)
    • 1x 400GbE OSFP with NVIDIA® CX-7 NDR (optional)
    • 4x 10GbE BaseT with Intel® X550 (optional)
    • View AOC Options
    • View AIOM Options
    IPMI
    • Support for Intelligent Platform Management Interface v.2.0
    • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
    Input / Output
    LAN
    • 1 RJ45 Dedicated BMC LAN port
    USB
    • 2 USB 2.0 port(s) (2 front)
    Video
    • 1 VGA port(s)
    System BIOS
    BIOS Type
    • AMI 256MB SPI Flash
    Management
    Software
    • IPMI 2.0
    • KVM with dedicated LAN
    • Super Diagnostics Offline
    • SuperDoctor® 5
    • Supermicro Update Manager (SUM)
    • Supermicro Power Manager (SPM)
    • Supermicro Server Manager (SSM)
    • Redfish API
    Power Configurations
    • ACPI Power Management
    • Power-on mode for AC power recovery
    Security
    Hardware
    • Trusted Platform Module (TPM) 2.0
    • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
    Features
    • Cryptographically Signed Firmware
    • Secure Boot
    • Secure Firmware Updates
    • Automatic Firmware Recovery
    • Supply Chain Security: Remote Attestation
    • Runtime BMC Protections
    • System Lockdown
    PC Health Monitoring
    CPU
    • Monitors for CPU Cores, Chipset Voltages, Memory
    FAN
    • Fans with tachometer monitoring
    • Pulse Width Modulated (PWM) fan connectors
    • Status monitor for speed control
    Temperature
    • Monitoring for CPU and chassis environment
    • Thermal Control for fan connectors
    Chassis
    Form Factor
    • 2U Rackmount
    Model
    • CSE-HE211-R000NFP
    Note
    • Standard sliding rail kit: Post to Post 19.1" ~ 26.4“
    Dimensions and Weight
    Height
    • 3.5" (88.9mm)
    Width
    • 17.2" (436.88mm)
    Depth
    • 22.6" (574mm)
    Package
    • 9.7" (H) x 23.5" (W) x 36.9" (D)
    Weight
    • Net Weight: 34.4 lbs (15.6 kg)
    • Gross Weight: 47.4 lbs (21.5 kg)
    Available Color
    • Silver
    Front Panel
    Buttons
    • Power On/Off 
    • UID button
    LEDs
    • HDD activity LED
    • LAN1 activity
    • LAN2 activity
    • Power Fail
    • Power status LED
    • System information
    Expansion Slots
    PCI-Express (PCIe)
    • 3 PCIe 5.0 x16 or x8 FHFL slot(s)
    • 3 (Optional) PCIe 5.0 x8 FHFL slot(s)
    • 1 PCIe 5.0 x8 or (Optional) x16 FHHL slot(s)
    • 1 PCIe 5.0 x8 FHHL or Disable slot(s)
    • View AOC Options
    Note
    • If Slot 1 is configured as PCIe x16, Slot 2 will be disabled; If Slot 3 is configured as PCIe x16, Slot 4 will be disabled; If Slot 5 is configured as PCIe x16, Slot 6 will be disabled; (Optional) If Slot 7 is configured as PCIe x16, Slot 8 will be disabled.
    Drive Bays / Storage
    Hot-swap
    • 6x 2.5" hot-swap NVMe/SATA/SAS drive bays (6x 2.5" NVMe hybrid) (SAS support requires additional parts. Please see the Optional Parts list.)
    • View Drive Options
    M.2
    • 2 M.2 NVMe OR 2 M.2 SATA3
    • M-Key, 2280/22110
    • View M.2 Options
    System Cooling
    Fans
    • 6 Counter-rotating, Hot-swappable 6cm Fan(s)
    Liquid Cooling
    • Direct to Chip (D2C) Cold Plate (optional)
    Power Supply
    2x 2000W Redundant Titanium (certification pending) Level power supplies
    Dimension

    (W x H x L)
    • 73.5 x 40 x 203 mm
    AC Input
    • 1000W: 100-127Vac / 50-60Hz
    • 1800W: 200-220Vac / 50-60Hz
    • 1980W: 220-230Vac / 50-60Hz
    • 2000W: 220-240Vac / 50-60Hz (for UL only)
    • 2000W: 230-240Vac / 50-60Hz
    • 2000W: 230-240Vdc / 50-60Hz (for China only)
    +12V
    • Max: 83A (100Vac-127Vac)
    • Max: 150A (200Vac-220Vac)
    • Max: 165A (220Vac-230Vac)
    • Max: 166A (230Vac-240Vac)
    12V SB
    • Max: 3.5A
    Output Type
    • Backplanes (gold finger)
    Operating Environment
    Environmental Spec.
    • Operating Temperature:
         0°C ~ 35°C (32°F ~ 95°F)
    • Non-operating Temperature:
         -40°C to 70°C (-40°F to 158°F)
    • Operating Relative Humidity:
         8% to 90% (non-condensing)
    • Non-operating Relative Humidity:
         5% to 95% (non-condensing)


    Parts List
    Standard Parts (Parts Included)
    Part Number Qty Description
    Motherboard / Chassis MBD-X13DEM

    CSE-HE211-R000NFP
    1

    1
    Super X13DEM Motherboard

    2U Chassis
    Add-on Card / Module AOM-AIOM-2X8-G5-P 1 AIOM adaptor board (cable solution), PCIe Gen-5,RoHS
    AOM-HE211-AIOM-X13-P 1 AIOM extension board for Hyper-E 2U, X13 MB,RoHS
    AOM-HS119-IO-P 1 Hyper IO Board,RoHS
    Backplane BPN-NVME5-HE211N-S6 1 1U 6-port all hybrids backplane support up to 6x SAS3/SATA3/NVME5 storage devices
    Cable CBL-GNZ4-1227M5YRR16 1 (GENZ 4C STR to 2 MCIO) x8 RA/RA 27/16cm,30#,RoHS
    CBL-MCIO-1213M5 2 MCIO x8 (STR to STR),13cm,85OHM,RoHS
    CBL-MCIO-1224AM5 2 [NR] MCIO (x8 STR to x8 STR), 24CM, LNRV, G5, 85OHM, RoHS
    CBL-MCIO-1230M5 1 [NR] MCIO x8 (STR to STR),30CM,85OHM,RoHS
    CBL-MCIO-1233M5R 1 MCIO x8 (STR to RA),33cm,85OHM,RoHS
    CBL-PWEX-1136YVB-45 1 (2x4 to 3 2x2), PH3.0,45cm,8.5A/p,18AWG,RoHS
    CBL-SAST-1243LP-85 1 SlimlineLP x8 (STR to STR),INT,30CM,85 OHM,RoHS
    CBL-SAST-1249LP-85 1 SlimlineLP x8 (STR) tp 2x SlimlineLP x4 (STR),49/61CM,8
    CBL-OTHR-1117 OR 1 2x15,PH1.0 to 2x15,PH1.0,28AWG,30CM,1A/pin,RoHS
    CBL-CDAT-1060-30 2x15,PH1.0 to 2x15,PH1.0,28AWG,30CM,1A/pin,RoHS
    CBL-MCIO-1218M5 OR 2 MCIO x8 (STR to STR),18CM,85OHM,RoHS
    CBL-MCIO-1218M5-1 MCIO x8 (STR to STR),18CM,85OHM,RoHS
    CBL-MCIO-1230M5R OR 1 MCIO x8 (STR to RA),30CM,85OHM,RoHS
    CBL-MCIO-1230M5R-1 [NR] MCIO x8 (STR to RA),30CM,85OHM,RoHS
    CBL-PWEX-1142-40 OR 1 MicroHi,(2x4 to 2x4),PH3.0,40CM,8A/pin,18AWG,RoHS
    CBL-PWEX-1142B-40 MicroHi(2x4 to 2x4), PH3.0, 40cm, 8.5A/p, 18AWG, RoHS
    CBL-CDAT-1290F 1 [NR] FRONT CNTL,20 TO 20 PIN,P0.5,FLAT,90CM,STD,RoHS
    CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
    CBL-PWEX-1104-8 1 [NR] 2x4,PH3.0,M to 2x3,PH2.0,F,3A/pin,22AWG,8CM
    Fan FAN-0215L4 6 60x60x56 mm, 17K-17K RPM, Counter-rotating Cooling Fan for 2U Hyper-E (CSE-HE211) Series Servers
    Air Shroud MCP-310-21106-0B 4 HE211 Mylar air shroud for X12DHM 8-Barlow Pass Memory,RoHS
    Power Supply PWS-2K08F-1R 2 1U 2000W 100-240VAC/50-60Hz, reverse airlfow
    Riser Card RSC-H-68G5 2 1U LHS Hyper Riser card with one PCIe 5.0 X16 and one P
    RSC-H2-6888G5S 1 2U LHS Hyper Riser card with one PCIe 5.0 X16 and thre
    Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
    Heatsink / Retention SNK-P0088PR 2 2U Proprietary Passive CPU Heat Sink for X13 Generation Hyper-E Series Servers
    *Front Panel FPB-FP826-T 1 Chassis front control board for SC826
    *Drive Tray(s) MCP-220-00178-0B 6 2.5 thin profile drive tray, Orange tab (for hotswap NVMe drive), for SC119UH
    Notes:
    1. Parts with * are inside the chassis
    2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
    Optional Parts List
    Part Number Qty Description
    Cable CBL-MCIO-1232M5 1 Optional cable for PCIe Slot 1 5.0 x8/ PCIe Slot 2 5.0 x8
    CBL-GNZ4-1227M5YR21 1 Optional cable for PCIe Slot 3 5.0 x8/ PCIe Slot 4 5.0 x8
    CBL-PWEX-1148-30 1 CPU 8-pin connector power cable for GPU installed on PCIe slot 5
    CBL-PWEX-1172-2654 1 CPU 8-pin connector power cable for GPU installed on PCIe slot 1 and PCIe slot 3
    CBL-PWEX-1171-2654 1 PCIe 8-pin connector power cable for GPU
    CBL-PWEX-0962Y-30 1 Power cable for H100 GPU installed on PCIe Slot 3
    CBL-PWEX-0962Y-20 1 Power cable for H100 GPU installed on PCIe Slot 1 and PCIe Slot 5
    Optional sliding rail kit MCP-290-11903-0N  1 30.5" ball-bearing rail set, without auto latch for Hyper 1U & 2U Project
    MCP-290-11901-0N  1 Optional sliding rail kit for Post to Post: 26.5" ~ 41.2"
    MCP-290-11902-0N  1 Optional sliding rail kit for Post to Post: 24" ~ 35.3"
    Riser Card RSC-H2-668G5S 1 Optional Riser Card for PCIe Slot 7 5.0 x16/ PCIe Slot 8 disable